Transkript
REVIEW
Catheter Ablation of Atrial Fibrillation Using Pulsed Field Ablation
Pulsed field ablation (PFA) has rapidly emerged as a leading ablation modality for the interventional treatment of atrial fibrillation (AF) and is increasingly used in contemporary clinical practice. PFA offers high procedural efficiency and reduces the risk of thermal collateral damage. However, this shift introduces novel complications, including intravascular haemolysis and proximity-related coronary vasospasm. This review explores the contemporary technological landscape, the shifting safety profile, and strategies for optimal patient selection.
Viviane Herren 1,2, Sujeena Balasundaram 1,2, Sven Knecht 1,2, Patrick Badertscher 1,2, Leon Pfeil 1,2, Stefanie Aeschbacher 1,2, Philipp Krisai 1,2, Leo H. Bonati 3, Christine S. Zuern 1,2, Felix Mahfoud 1,2, Christian Sticherling 1,2, Michael Kühne 1,2
ABSTRACT
Background: Over the past three decades, thermal ablation modalities defined atrial fibrillation (AF) treatment. By 2026, pulsed field ablation (PFA) has gained widespread adoption and is becoming an increasingly important modality for AF ablation. Aim: To provide an up-to-date overview of AF ablation in 2026, focusing on efficacy, the integration of PFA with 3D mapping, procedural efficiency, evolving complication profiles, and contemporary approaches to individualized patient selection and shared decision-making. Summary: Data from recent pivotal trials and large-scale registries demonstrate that PFA is at least as effective and more efficient compared to thermal ablation of AF. The safety profile has shifted, with previously recognized thermal complications, such as atrio-oesophageal fistulae and persistent phrenic nerve palsy, now being extremely rare with PFA. However, non-thermal tissue electroporation introduces modality-specific adverse events. A key safety consideration in PFA is the management of proximity-related coronary vasospasm, especially during cavotricuspid isthmus ablation, alongside intravascular haemolysis that may rarely lead to acute kidney injury. Conclusion: PFA provides high workflow efficiency and minimizes thermal collateral damage compared to thermal ablation platforms. While efficacy and efficiency are favourable, active management of potential PFA-specific risks is necessary, and definitive long-term arrhythmia-free survival data compared to thermal modalities remain subject to ongoing evaluation.
Keywords: Pulsed field ablation, atrial fibrillation, 3D mapping, complications, patient selection
Introduction Catheter ablation for atrial fibrillation (AF) has steadily evolved into the cornerstone of interventional rhythm control, relying historically on thermal energy sources. Building on the seminal discovery by Haïssaguerre and colleagues in 1998 that AF is primarily triggered by ectopic beats origi-
nating in the pulmonary veins (1), the field progressed from point-by-point radiofrequency ablation (RFA) to single-shot cryoballoon technologies. During this era, ablation has proven superior to antiarrhythmic drugs for maintaining sinus rhythm, as established by landmark trials such as A4 and RAAFT-2 (2,3). Furthermore, the clinical paradigm has shifted toward early rhythm control (EAST-AFNET 4) (4) and first-line ablation strategies (EARLY-AF, STOP AF First) (5,6), continuously expanding procedural volumes.
While clinically effective, all the different thermal modalities achieve pulmonary vein isolation (PVI) through conductive heating or freezing. This propagates energy contiguously through tissues, carrying an inherent risk of thermal collateral damage to adjacent anatomical structures. The necessity to avoid these complications previously limited the speed and extent of ablation procedures.
Evolving Role in AF Ablation Following early proof-of-concept studies such as IMPULSE and PEFCAT (7), pulsed field ablation (PFA) has emerged as a non-thermal alternative utilizing irreversible electroporation (IRE). The biophysical mechanism differs fundamentally from the immediate coagulative necrosis caused by thermal methods such as radiofrequency ablation (RFA) or cryoablation. PFA delivers ultra-short, high-voltage electrical pulses that destabilize cell membranes, creating nanoscale pores. If this disruption of homeostasis is of sufficient magnitude, the cell cannot restore normal function and undergoes programmed cell death, predominantly via apoptosis (8,9).
A hallmark of PFA is its tissue selectivity. Myocardial tissue has a low threshold for electroporation, whereas adjacent tissues, including oesophageal smooth muscle, vascular endothelium, and nerve fibres, are considerably more resist-
1 Clinic for Cardiology, University Hospital Basel, University of Basel, Basel, Switzerland 2 Cardiovascular Research Institute Basel, University Hospital Basel, University of Basel, Basel, Switzerland 3 Rheinfelden Rehabilitation Clinic, Rheinfelden, Switzerland
ars medici 11 | 2026 543
REVIEW
ant. This allows for effective lesion creation while sparing critical contiguous structures (9). The 2023 ACC/AHA/ACCP/ HRS and 2024 ESC guidelines gave Class I recommendations for catheter ablation, including PVI as the primary lesion set in selected patients with symptomatic paroxysmal AF, but they did not make energy-source-specific recommendations for PFA (10,11,). Subsequent randomized trials and the 2026 EHRA/HRS/APHRS/LAHRS/CHRS scientific statement support PFA as an effective alternative to radiofrequency and cryoballoon ablation, with potential safety and procedural-efficiency advantages (9,12,13). Whether it should be considered the universal primary standard of care remains to be determined in future studies.
tent AF, where tailored contiguous ablation lesions beyond PVI (e.g., posterior wall isolation or mitral isthmus line) may be required (Figure 2) (15). Data from pivotal randomized trials, such as ADVENT (13), and large-scale real-world registries, such as EU-PORIA (16), consistently demonstrate that these integrated PFA workflows yield substantially shorter skin-to-skin procedure times compared to thermal modalities (13,14,16).
The Evolution of 3D Mapping The rapid clinical adoption of PFA has been accelerated by its integration with 3D electroanatomical mapping (EAM) systems. While pre-procedural imaging with computed tomography (CT) or magnetic resonance imaging (MRI) may be obtained to characterize pulmonary vein anatomy, intra-procedural guidance has evolved significantly. During early PFA development, platforms lacked mapping capabilities, necessitating fluoroscopy-guided workflows or preand post-procedural mapping using multipolar catheters in conjunction with available EAM systems. This required additional sheath exchanges, increasing procedural complexity and the risk of cerebral embolic events (9).
Routine integration with 3D mapping is now widely available for different PFA platforms. It allows for precise lesion-tagging and ensures contiguous ablation lines with the goal to achieve transmural lesions. Whereas no randomized trial has been shown to increase freedom from AF using an EAM system, its use is associated with reduced fluoroscopy exposure. While the rapidly expanding commercial landscape offers a multitude of PFA catheter geometries, two fundamental conceptual approaches dominate contemporary practice. The following two distinct catheter designs serve as representative examples: • Anatomical Mapping using a multi-spline catheter
(e. g., FARAWAVE NAV, Boston Scientific): This system employs an over-the-wire, multi-electrode pentaspline catheter designed for PVI using PFA. The FARAVIEW software specifically integrates the catheter with its proprietary EAM system (OPAL), facilitating fast anatomical reconstruction of the left atrium and real-time lesion tagging. Energy is delivered in a basket or flower configuration for PVI and lesions beyond PVI (Figure 1) (14). • High-Density Focal Mapping using a large-footprint catheter (e. g., Affera Sphere-9, Medtronic): Multi-electrode large-footprint catheters combine high-density mapping with ablation (PFA and RFA) within a lattice-tip. The flexible mesh-like tip equipped with microelectrodes allows for detailed substrate mapping to identify specific electrophysiological targets and delivery of dual-energy ablation (toggling between RFA and PFA). This is relevant for persistent and long-standing persis-
Figure 1: 3D Electroanatomical Mapping using a multi-spline catheter (FARAWAVE NAV, Boston Scientific). The pentaspline system (FARAPULSE), initially reliant on a fluoroscopy-guided workflow, demonstrates contemporary integration with 3D mapping in the OPAL system for realtime catheter visualization. A postero-anterior view of the left atrium with the pentaspline catheter in a basket configuration at the ostium of the left superior pulmonary vein. All 4 pulmonary veins are isolated in a patient after PVI (ablated areas with low voltage shown in red). (Image provided by the University Hospital Basel)
Figure 2: High-Density Focal Mapping using a large-footprint catheter (Affera Sphere-9, Medtronic). The platform operates exclusively with mapping integration, providing high-density voltage maps to delineate prior ablation lesions and low voltage areas. Left: A postero-anterior view of the left atrium in a patient with recurrence of AF after a previous PVI. Mapping shows residual signals at the right inferior pulmonary vein and low voltage areas at the posterior wall. Right: Isolation of the posterior wall using the Affera Sphere-9 dual-energy large-footprint catheter (Anterior roof line using RFA (red dots) and posterior line using PFA (green dots). (Images provided by the University Hospital Basel)
544 ars medici 11 | 2026
REVIEW
Complication Profiles: Thermal vs. Electroporation The transition to PFA has fundamentally altered the procedural risk profile. Real-world data and comparative randomized and non-randomized analyses demonstrate that PFA is associated with both a similar overall incidence of adverse events, however the types of complications are significantly different (14,17,18). While generic catheterization risks (e. g., vascular access site complications, cardiac tamponade, stroke, or transient ischaemic attack) remain comparable across all modalities, the mechanism of tissue injury has shifted from thermal contiguity to electrical field effects. This requires a distinctly different approach to complication management (Figure 3).
transient and persistent phrenic nerve palsy remained a recognized complication. • Pulmonary Vein Stenosis: Direct thermal injury inside the tubular structure of the vein ostium could cause fibrotic remodelling and subsequent narrowing of the vessel. Registry data, including the comprehensive MANIFEST-17K cohort, demonstrate that the tissue-selective properties of electroporation have substantially reduced the incidence of these thermal injuries, reporting near-zero rates of phrenic nerve palsy and pulmonary vein stenosis, and no atrio-oesophageal fistulae (14,20). Of note, the incidence of pericarditis has also been reported to be very low (approximately 0.1 – 0.2%) with PFA (20–22).
Figure 3: The Shifting Safety Paradigm in Atrial Fibrillation Ablation. A comprehensive side-by-side comparison of complication profiles between thermal ablation (radiofrequency and cryoballoon) and non-thermal pulsed field ablation (PFA). While PFA's tissue selectivity mitigates classical risks such as atrio-oesophageal fistulae, pulmonary vein stenosis, and phrenic nerve palsy, it introduces specific adverse events, notably proximity-related coronary vasospasm and dose-dependent intravascular haemolysis. (Created with BioRender.com)
The Mechanism of Thermal Injury Thermal ablation modalities (RFA and cryoablation) relied on conductive energy transfer, which inherently affects any tissue in direct contact with or in close proximity to the ablation site. This non-selective mechanism led to several specific procedural risks (17,19): • Atrio-oesophageal Fistulae (AEF): During ablation of
the posterior left atrial wall, thermal energy could conduct through the thin myocardial wall into the adjacent anterior oesophagus, causing ischaemic necrosis. Despite the use of oesophageal temperature probes, this rare but life-threatening complication remained a clinical limitation of thermal ablation. • Phrenic Nerve Palsy (PNP): The right phrenic nerve descends in close anatomical proximity to the right superior pulmonary vein. Contiguous freezing from a cryoballoon or less frequently heat from an RFA catheter could result in direct thermal injury to the nerve fibres. While continuous phrenic nerve pacing was used as a monitoring tool during cryoablation to prematurely halt energy delivery,
Modality-Specific PFA Adverse Events While thermal risks are mitigated, the application of high-voltage electrical fields introduces modality-specific risks that operators must actively manage (9,14): • Proximity-related Coronary Vasospasm: Proximity-re-
lated coronary vasospasm has been documented during PFA, particularly during ablation of the cavotricuspid isthmus (CTI) or mitral isthmus (23). In the MANIFEST-17K registry, coronary spasm occurred in 0.14% of patients (14). Pathophysiologically, this relates to transient functional electroporation of vascular smooth muscle cells or local autonomic effects. Current clinical consensus recommends the prophylactic or therapeutic administration of intracoronary or intravenous nitroglycerin prior to ablating in close proximity to coronary arteries (9,23,24). • Intravascular Haemolysis and Acute Kidney Injury (AKI): The electrical fields generated during PFA cause pore formation in erythrocytes passing near the active electrode, leading to intravascular haemolysis (25). This phenomenon is dose-dependent, correlating directly with the number of PFA applications. While subclinical haemolysis is common, severe cases resulting in haptoglobin depletion and AKI requiring temporary haemodialysis occur in rare instances (0.03% in MANIFEST-17K) (14). Pre- and intra-procedural intravenous hydration may be used to maintain renal perfusion and minimize tubular toxicity (9,25). Interestingly, in a non-randomized comparison of 2570 patients undergoing AF ablation, PFA was associated with a 1% incidence of AKI, which was lower compared with thermal ablation (26). • Myocardial Injury (Troponin Elevation): PFA procedures are associated with a significantly higher post-procedural release of cardiac biomarkers (high-sensitivity troponin) compared to thermal ablation (27). It is an expected physiological response to ablation and has not been associated with adverse clinical outcomes. Interestingly, there are marked differences in myocardial injury across different PFA platforms (28).
Efficacy Profile While the procedural efficiency and specific safety profile of PFA are well documented, its long-term efficacy remains the
ars medici 11 | 2026 545
REVIEW
subject of ongoing evaluation. Initial pivotal trials, including ADVENT and PULSED AF, demonstrated that PFA is noninferior to conventional RFA and cryoballoon ablation regarding 1-year arrhythmia-free survival for paroxysmal AF (12,13). Recent randomized trials, including BEAT PAROX AF and SINGLE SHOT CHAMPION, demonstrated that PFA is at least as effective as thermal ablation for paroxysmal AF. Notably, SINGLE SHOT CHAMPION, using continuous rhythm monitoring with implantable loop recorders, showed non inferiority and a borderline superiority of PFA over cryoballoon for 1 year arrhythmia free survival (P = 0.046 for superiority) (18,19).
In persistent AF, where the substrate is often characterized by advanced left atrial cardiomyopathy and fibrosis, PFA’s ability to create extensive lesion sets (e.g., posterior wall isolation) without the risk of thermal oesophageal injury provides a potential procedural advantage (15). A recent randomized trial (PIFPAF-PFA) analysing the potential incremental value of posterior wall ablation in addition to PVI in patients with persistent AF was negative regarding the primary endpoint of atrial arrhythmia recurrence lasting > 30 seconds after 1 year, but there was a significant difference favouring additional posterior wall ablation regarding recurrences with longer duration (> 1 hour). However, these findings are hypothesis generating and merit further investigation (30).
Finally, whereas re-mapping studies with PFA indicate high rates of durable PVI, more randomized data beyond 1 to 5 years are required to determine whether PFA suppresses arrhythmia progression more effectively than thermal technologies in the long term (31).
Patient Selection & Management Guided by the 2024 ESC Guidelines and international expert consensus, patient selection strategies are evolving to leverage the specific safety and efficiency profiles of modern PFA systems (9,11,32). Rather than a niche technology, PFA has rapidly become a preferred modality across a broad spectrum of AF phenotypes. Crucially, modern management emphasizes robust shared decision-making, ensuring that patient values, bleeding risks, and individual symptom burden are thoroughly integrated into the procedural roadmap.
Repeat Ablation (Redo Procedures) Patient selection for redo procedures may favour PFA platforms with integrated high-density 3D mapping. Largescale registry data have reported on the safety and effectiveness of PFA in repeat interventions, but randomized trials using PFA for repeat ablation are lacking (36). In redo settings after prior failed thermal ablation, high-density mapping delineates PV reconnections prior to PFA delivery (37,38). However, the optimal lesion set in redo procedures especially in case of persistent isolation of all pulmonary veins is still unclear.
Specific Vulnerable Populations The procedural characteristics of PFA require specific considerations for several clinical subgroups: • Heart Failure with Reduced Ejection Fraction (HFrEF):
Specific patient populations with AF and heart failure may benefit from AF ablation (39,40). With PFA, shorter procedure times reduce the duration of sedation or anaesthesia, and the fluid-neutral profile avoids the volume overload seen with irrigated radiofrequency ablation, thereby lowering the risk of peri-procedural acute decompensated heart failure. • Elderly and Frail Patients: Because modern PFA workflows enable shorter procedures that can often be performed under deep sedation rather than general anaesthesia, the risks of postoperative delirium and prolonged recovery may be reduced. This makes PFA an appealing option for octogenarians and frail patients (41). However, this potential advantage has not been tested in a randomized setting. • Left Atrial Appendage Occlusion (LAAO) and Cardiac Implantable Electronic Devices (CIEDs): While PFA simplifies many procedural aspects, specific aspects require caution. In patients with pre-existing lobe-and-disk LAA occluders or those with CIEDs (e.g., pacemakers and implantable cardioverter-defibrillators), operators must carefully navigate to avoid energy delivery in direct contact with device leads or metallic occluder components (9,32,42,43).
De Novo Atrial Fibrillation For de novo paroxysmal AF, PFA has demonstrated substantial clinical advantages, establishing it as an optimal firstline strategy (9). High-quality randomized data confirm the robust safety and acute efficacy of PFA in this setting (18). Furthermore, PFA mitigates acute and long-term complications, with evidence indicating that phrenic nerve palsy, atrio-oesophageal fistula, and pulmonary vein stenosis are largely absent following PFA compared to thermal modalities (9,33).
In persistent AF, where ablation beyond PVI may be performed, PFA’s tissue selectivity enables extensive substrate modification without the risks historically associated with thermal energy, especially with ablation at the posterior wall (15,34,35). However, more robust randomized trials are needed in this patient population.
Conclusion The current landscape of AF ablation includes the widespread adoption of PFA integrated with mapping systems. This combination provides procedural efficiency and mitigates the risk of thermal collateral injuries previously associated with radiofrequency and cryoballoon ablation. While the short- to medium-term safety and efficacy profiles are comparable to thermal methods, the shift to non-thermal energy requires clinicians to actively manage modality-specific risks, particularly proximity-related coronary vasospasm and intravascular haemolysis. Ultimately, although PFA is becoming the contemporary standard of care for pulmonary vein isolation, long-term arrhythmia-free survival will require further longitudinal evaluation.
546 ars medici 11 | 2026
REVIEW
KEY MASSAGES
• Technological Shift: Pulsed field ablation (PFA) has replaced thermal modalities as the standard of care, utilizing tissue-selective irreversible electroporation.
• Workflow Efficiency: The integration of PFA with 3D electroanatomical mapping (EAM) is transforming procedures, enabling rapid procedures with low radiation exposure.
• Shifting Safety Paradigm: The incidence of thermal collateral damage (e. g., atrio-oesophageal fistulae, phrenic nerve palsy, pulmonary vein stenosis) is substantially reduced compared to thermal ablation. The clinical focus has shifted to managing PFA-specific adverse events, including proximity-related coronary vasospasm and intravascular haemolysis-induced acute kidney injury.
• Individualized Selection: Patient management relies on targeted phenotypic stratification, supported by comprehensive shared decision-making.
• Clinical Outlook: While currently available trial data show that PFA is at least as effective as thermal ablation, long-term arrhythmia-free survival data in different AF phenotypes and patient populations are still the subject of ongoing clinical investigation.
SUGGESTED READING
• Van Gelder IC et al.: 2024 ESC Guidelines for the management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2024;45(36):3314-3414. doi:10.1093/eurheartj/ehae176
• Kühne M et al.: Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society. Europace. 2026;28(6):euag080. doi:10.1093/europace/euag080
• Ekanem E et al.: Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study. Nat Med. 2024;30(7):2020-2029. doi:10.1038/s41591-024-03114-3
• Reichlin T, et al.: Pulsed Field or Cryoballoon Ablation for Paroxysmal Atrial Fibrillation. New England Journal of Medicine. 2025;392(15):1497-1507. doi:10.1056/NEJMoa2502280
Address for correspondence: Prof. Dr. Michael Kühne University Heart Center University Hospital Basel Petersgraben 4 4031 Basel Switzerland E-Mail: michael.kuehne@usb.ch
References: 1. Haïssaguerre M et al.: Spontaneous initiation of atrial fibrillation by
ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339(10):659-666. doi:10.1056/NEJM199809033391003 2. Jaïs P et al.: Catheter ablation versus antiarrhythmic drugs for atrial fibrillation: the A4 study. Circulation. 2008;118(24):2498-2505. doi:10.1161/CIRCULATIONAHA.108.772582
3. Morillo CA et al.: Radiofrequency Ablation vs Antiarrhythmic Drugs as First-Line Treatment of Paroxysmal Atrial Fibrillation (RAAFT-2): A Randomized Trial. JAMA. 2014;311(7):692-699. doi:10.1001/jama.2014.467
4. Kirchhof P et al.: Early Rhythm-Control Therapy in Patients with Atrial Fibrillation. New England Journal of Medicine. 2020;383(14):13051316. doi:10.1056/NEJMoa2019422
5. Andrade JG et al.: Cryoablation or Drug Therapy for Initial Treatment of Atrial Fibrillation. New England Journal of Medicine. 2021;384(4):305315. doi:10.1056/NEJMoa2029980
6. Wazni OM et al.: Cryoballoon Ablation as Initial Therapy for Atrial Fibrillation. N Engl J Med. 2021;384(4):316-324. doi:10.1056/NEJMoa2029554
7. Reddy VY et al.: Ablation of Atrial Fibrillation With Pulsed Electric Fields: An Ultra-Rapid, Tissue-Selective Modality for Cardiac Ablation. JACC Clin Electrophysiol. 2018;4(8):987-995. doi:10.1016/j.jacep.2018.04.005
8. Koruth JS et al.: Pulsed Field Ablation Versus Radiofrequency Ablation. Circ Arrhythm Electrophysiol. 2020;13(3):e008303. doi:10.1161/CIRCEP.119.008303
9. Kühne M et al.: Pulsed field ablation for the interventional treatment of atrial fibrillation: a scientific statement of the European Heart Rhythm Association of the European Society of Cardiology, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, the Latin American Heart Rhythm Society, and the Canadian Heart Rhythm Society. Europace. 2026;28(6):euag080. doi:10.1093/europace/euag080
10. Joglar J et al.: 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation. J Am Coll Cardiol. 2024;83(1):109-279. doi:10.1016/j.jacc.2023.08.017
11. Van Gelder IC et al.: 2024 ESC Guidelines for the management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J. 2024;45(36):33143414. doi:10.1093/eurheartj/ehae176
12. Verma A et al.: Pulsed Field Ablation for the Treatment of Atrial Fibrillation: PULSED AF Pivotal Trial. Circulation. 2023;147(19):14221432. doi:10.1161/CIRCULATIONAHA.123.063988
13. Reddy VY et al.: Pulsed Field or Conventional Thermal Ablation for Paroxysmal Atrial Fibrillation. New England Journal of Medicine. 2023;389(18):1660-1671. doi:10.1056/NEJMoa2307291
14. Ekanem E et al.: Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study. Nat Med. 2024;30(7):2020-2029. doi:10.1038/s41591-024-03114-3
15. Anter E et al.: Dual-energy lattice-tip ablation system for persistent atrial fibrillation: a randomized trial. Nat Med. 2024;30(8):2303-2310. doi:10.1038/s41591-024-03022-6
16. Kueffer T et al.: Durability of Pulmonary Vein Isolation Using PulsedField Ablation: Results From the Multicenter EU-PORIA Registry. JACC Clin Electrophysiol. 2024;10(4):698-708. doi:10.1016/j.jacep.2023.11.026
17. Cho MS et al.: Complications associated with pulsed field ablation vs radiofrequency catheter ablation of atrial fibrillation. Heart Rhythm. 2025;22(9):2194-2200. doi:10.1016/j.hrthm.2024.10.063
18. Reichlin T et al.: Pulsed Field or Cryoballoon Ablation for Paroxysmal Atrial Fibrillation. New England Journal of Medicine. 2025;392(15):1497-1507. doi:10.1056/NEJMoa2502280
19. Benali K et al.: Procedure-Related Complications of Catheter Ablation for Atrial Fibrillation. JACC. 2023;81(21):2089-2099. doi:10.1016/j.jacc.2023.03.418
20. Turagam MK et al.: Safety and Effectiveness of Pulsed Field Ablation to Treat Atrial Fibrillation: One-Year Outcomes From the MANIFEST-PF Registry. Circulation. 2023;148(1):35-46. doi:10.1161/CIRCULATIONAHA.123.064959
21. Schmidt B et al.: EUropean real-world outcomes with Pulsed field ablatiOn in patients with symptomatic atRIAl fibrillation: lessons from the multi-centre EU-PORIA registry. Europace. 2023;25(7):euad185. doi:10.1093/europace/euad185
22. Isenegger C et al.: Incidence of acute pericarditis after pulsed-field ablation for the treatment of atrial fibrillation. Europace. 2024;26(7): euae180. doi:10.1093/europace/euae180
23. Reddy VY et al.: Coronary Arterial Spasm During Pulsed Field Ablation to Treat Atrial Fibrillation. Circulation. 2022;146(24):1808-1819. doi:10.1161/CIRCULATIONAHA.122.061497
24. Gerstenfeld EP et al.: Pulsed Field Ablation vs Standard Radiofrequency Ablation for Typical Atrial Flutter: ADVANTAGE AF Trial Substudy. JACC. 2026;87(14):1764-1778. doi:10.1016/j.jacc.2025.12.081
25. De Smet MAJ et al.: Intravascular haemolysis and acute kidney injury following atrial fibrillation ablation: a report using two different systems for pulsed field ablation. Europace. 2024;26(10):euae251. doi:10.1093/europace/euae251
26. Jordan F et al.: Acute kidney injury after catheter ablation of atrial fibrillation: Comparison between different energy sources. Heart Rhythm. 2024;21(8):1248-1249. doi:10.1016/j.hrthm.2024.04.046
ars medici 11 | 2026 547
REVIEW
27. Krisai P et al.: Troponin release after pulmonary vein isolation using pulsed field ablation compared to radiofrequency and cryoballoon ablation. Heart Rhythm. 2022;19(9):1471-1472. doi:10.1016/j.hrthm.2022.05.020
28. Badertscher P et al.: Extent of myocardial injury after pulmonary vein isolation using 3 different pulsed field ablation systems. Heart Rhythm. 2025;22(9):2437-2439. doi:10.1016/j.hrthm.2025.03.1884
29. Jais P et al.: Pulsed field vs radiofrequency ablation for paroxysmal atrial fibrillation: the BEAT PAROX-AF trial. Eur Heart J. 2026;47(13):1527-1537. doi:10.1093/eurheartj/ehaf1115
30. Roten L et al.: Pulmonary Vein Isolation Using Pulsed Field Ablation With vs Without Posterior Wall Isolation in Patients With Symptomatic Persistent Atrial Fibrillation: The PIFPAF-PFA Randomized Clinical Trial. JAMA. Published online August 29, 2026:e2617598. doi:10.1001/jama.2026.17598
31. Natale A et al.: Catheter ablation for atrial fibrillation: indications and future perspective. Eur Heart J. 2024;45(41):4383-4398. doi:10.1093/eurheartj/ehae618
32. Tzeis S et al.: 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2024;26(4):euae043. doi:10.1093/europace/euae043
33. Mansour M et al.: Pulmonary vein narrowing after pulsed field versus thermal ablation. Europace. 2024;26(2):euae038. doi:10.1093/ europace/euae038
34. Reddy VY et al.: Pulsed Field Ablation for Persistent Atrial Fibrillation: 1-Year Results of ADVANTAGE AF. J Am Coll Cardiol. 2025;85(17):16641678. doi:10.1016/j.jacc.2025.03.515
35. Chorin E et al.: Ablation in persistent atrial fibrillation: High long-term success with pulsed field ablation using a strict protocol. Heart Rhythm. 2025;22(12):e1214-e1220. doi:10.1016/j.hrthm.2025.08.035
36. Scherr D et al.: Repeat procedures after pulsed field ablation for atrial fibrillation: MANIFEST-REDO study. Europace. 2025;27(8):euaf012. doi:10.1093/europace/euaf012
37. Tohoku S et al.: Findings from repeat ablation using high-density mapping after pulmonary vein isolation with pulsed field ablation. Europace. 2023;25(2):433-440. doi:10.1093/europace/euac211
38. Maurhofer J et al.: Pulsed-field ablation for repeat procedures after failed prior thermal ablation for atrial fibrillation. Heart Rhythm O2. 2024;5(5):257-265. doi:10.1016/j.hroo.2024.03.012
39. Marrouche NF et al.: Catheter Ablation for Atrial Fibrillation with Heart Failure. New England Journal of Medicine. 2018;378(5):417-427. doi:10.1056/NEJMoa1707855
40. Sohns C et al.: Catheter Ablation in End-Stage Heart Failure with Atrial Fibrillation. New England Journal of Medicine. 2023;389(15):13801389. doi:10.1056/NEJMoa2306037
41. Bergonti M et al.: Pulsed field ablation for atrial fibrillation ablation: a European Heart Rhythm Association survey. Europace. 2025;27(12): euaf294. doi:10.1093/europace/euaf294
42. Schaerli N et al.: Unexpected ventricular fibrillation during left ventricular lattice-tip radiofrequency ablation in a patient with an ICD. Heart Rhythm. 2026;23(5):1032-1034. doi:10.1016/j.hrthm.2025.11.046
43. Molitor N et al.: Percutaneous left atrial appendage occluders can impair pulmonary vein isolation by pulsed field ablation. Heart Rhythm. 2025;22(9):e801-e803. doi:10.1016/j.hrthm.2025.01.047
548 ars medici 11 | 2026